ISO 16063-11:1999 PDF

Methods for the calibration of vibration and shock transducers — Part 11: Primary vibration calibration by laser interferometry

First page of standard ISO 16063-11:1999Open preview (PDF)Methods for the calibration of vibration and shock transducers — Part 11: Primary vibration calibration by laser interferometry
Title (English):
ISO 16063-11:1999

Methods for the calibration of vibration and shock transducers — Part 11: Primary vibration calibration by laser interferometry

Document status:
Active
Format:
Electronic (PDF)
Number of pages:
27
Publication date:
December 16, 1999
Edition:
ISO IS 16063 edition 1 version 1
ICS:
17.160
Description (English):

This part of ISO 16063 specifies the instrumentation and procedure to be used for primary vibration calibration of rectilinear accelerometers (with or without amplifier) to obtain magnitude and phase lag of the complex sensitivity by steady-state sinusoidal vibration and laser interferometry. It is applicable to a frequency range from 1 Hz to 10 kHz and a dynamic range (amplitude) from 0,1 m/s2 to 1 000 m/s2 (frequency-dependent). These ranges are covered with the uncertainty of measurement specified in clause 2. Calibration frequencies lower than 1 Hz (e.g. 0,4 Hz, which is a reference frequency used in other International Standards) and acceleration amplitudes smaller than 0,1 m/s2 (e.g. 0,004 m/s2 at 1 Hz) can be achieved using Method 3 specified in this part of ISO 16063, in conjunction with an appropriate low-frequency vibration generator. Method 1 (fringe-counting method) is applicable to sensitivity magnitude calibration in the frequency range 1 Hz to 800 Hz and, under special conditions, at higher frequencies (cf. clause 7). Method 2 (minimum-point method) can be used for sensitivity magnitude calibration in the frequency range 800 Hz to 10 kHz (cf. clause 8). Method 3 (sine-approximation method) can be used for magnitude of sensitivity and phase calibration in the frequency range 1 Hz to 10 kHz (cf. clause 9). Methods 1 and 3 provide for calibrations at fixed acceleration amplitudes at various frequencies. Method 2 requires calibrations at fixed displacement amplitudes (acceleration amplitude varies with frequency).

Technical details

Technical committee
ISO/TC 108 - Mechanical vibration, shock and condition monitoring
SKU
ISO 16063-11:1999