Перейти к содержимому
Low prices. Originals and translations — save time and budget.

ISO 3951-1:2022 PDF

Sampling procedures for inspection by variables — Part 1: Specification for single sampling plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection for a single quality characteristic and a single AQL

First page of standard ISO 3951-1:2022Open preview (PDF)Sampling procedures for inspection by variables — Part 1: Specification for single sampling plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection for a single quality characteristic and a single AQL
Title (English):
ISO 3951-1:2022

Sampling procedures for inspection by variables — Part 1: Specification for single sampling plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection for a single quality characteristic and a single AQL

Document status:
Active
Format:
Electronic (PDF)
Number of pages:
114
Publication date:
August 18, 2022
Edition:
ISO IS 3951 edition 3 version 1
ICS:
03.120.30
Description (English):

This document specifies single sampling plans for lot-by-lot inspection under the following conditions: a) where the inspection procedure is applied to a continuing series of lots of discrete products, all supplied by one producer using one production process; b) where only a single quality characteristic, x, of these products is taken into consideration, which is measurable on a continuous scale; c) where production is under statistical control and the quality characteristic, x, is distributed according to a normal distribution or a close approximation to the normal distribution; d) where a contract or standard defines a lower specification limit, L, an upper specification limit, U, or both. An item is qualified as conforming if its measured quality characteristic, x, satisfies as appropriate one of the following inequalities: 1) x ≥ L (i.e. the lower specification limit is not violated); 2) x ≤ U (i.e. the upper specification limit is not violated); 3) x ≥ L and x ≤ U (i.e. neither the lower nor the upper specification limit is violated). Inequalities 1) and 2) are cases with a single specification limit, and 3) is a case with double specification limits. Where double specification limits apply, it is assumed in this document that conformity to both specification limits is equally important to the integrity of the product. In such cases, it is appropriate to apply a single AQL to the combined percentage of a product outside the two specification limits. This is referred to as combined control.

Technical details

Technical committee
ISO/TC 69/SC 5 - Acceptance sampling
SKU
ISO 3951-1:2022

This site uses cookies and visit counters for operation and statistics. Privacy policy