Перейти к содержимому
Low prices. Originals and translations — save time and budget.

ISO 16063-34:2019 PDF

Methods for the calibration of vibration and shock transducers — Part 34: Testing of sensitivity at fixed temperatures

First page of standard ISO 16063-34:2019Open preview (PDF)Methods for the calibration of vibration and shock transducers — Part 34: Testing of sensitivity at fixed temperatures
Title (English):
ISO 16063-34:2019

Methods for the calibration of vibration and shock transducers — Part 34: Testing of sensitivity at fixed temperatures

Document status:
Active
Format:
Electronic (PDF)
Number of pages:
16
Publication date:
December 16, 2019
Edition:
ISO IS 16063 edition 1 version 1
ICS:
17.160
Description (English):

This document details specifications for the instrumentation and methods to be used for testing fixed temperature sensitivity of vibration transducers. It applies to rectilinear velocity and acceleration transducers. The methods specified use both a comparison to a reference transducer and an absolute measurement by laser interferometer. This document is applicable for a frequency range from 10 Hz to 3 kHz (method-dependent), a dynamic range from 1 m/s2 to 100 m/s2 (frequency-dependent) and a temperature range from ?190 °C to 800 °C (method-dependent). Although it is possible to achieve these ranges among all the described systems, generally each has limitations within them. Method 1 (using a laser interferometer) is applicable to magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 3 kHz at fixed temperatures (see Clause 7). Method 2 (using a reference transducer inside a chamber whose temperature limit is ?70 °C to 500 °C) can be used for magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 1 kHz at fixed temperatures (see Clause 8). Method 3 (using a reference transducer outside the chamber) can only be used for the determination of the temperature response of complex sensitivity over a certain temperature range (see Clause 9). NOTE Method 1 and Method 2 can provide the deviation of complex sensitivity over a certain temperature range if the calibration is also done at the reference temperature (room temperature 23 °C ± 5 °C). To ensure the consistency of the use and test condition, the transducer, its cable and the conditioning amplifier are intended to be considered as a single unit and tested together.

Technical details

Technical committee
ISO/TC 108 - Mechanical vibration, shock and condition monitoring
SKU
ISO 16063-34:2019

This site uses cookies and visit counters for operation and statistics. Privacy policy